Error 91 is a very common error that Dynamics SL clients are receiving very often when exporting to excel. It occurs mainly in Frx 6.7 sp9 or sp10.
Error 91 - Object Variable or width Block Variable not set
This main cause of this error is that the supplemental updates for Frx 6.7 were not run. This error re-occurs after the month has been closed in GL.
To fix this issue,
1)Have everyone exit Solomon and Frx and make a backup of the Frx code folder.
2)Go to the Shared Solomon Directory and bring up the Frx67 folder.
3)Locate the Frxreg67.cmd and open it up. This will launch a MS-DOS screen and will automatically close once it's done.
IMPORTANT NOTE : DO NOT RUN FRXREG.EXE AFTER RUNNING FRXREG67.CMD AND THIS WILL REMOVE THE SUPPLEMENTAL UPDATES JUST INSTALLED.

0 Comments:
Post a Comment
<< Home